DGS ERIS-210 gas detector

roll over image to zoom in


Dear customers!

We inform you that DGS ERIS 210 gas detector has been redesigned.

The use of previously produced sensors and electronic components with any new series of gas detectors is limited.

1) Use only the supplied electronic module with the gas detector (the serial number of the electronic module and the gas detector must be identical).

2) Use only the supplied sensor with the gas detector.

3) Use only the supplied visual and audible alarm with the gas detector.

To order spare parts, please inform us about the serial number of the device to exclude the supply of inappropriate spare parts.

Failure to follow these instructions can result in device damage!

DGS ERIS 210 is a reliable explosion-proof gas detector used for flammable, toxic gases and oxygen monitoring in hazardous areas - indoors and outdoors. ERIS gas detectors meet the customized demands on no false alarms, longer service life and drift-free signal outputs. Intelligent SМART SENSOR technology provides an economic solution for gas monitoring as а variety of sensors can be easily replaced.

Advantages

Applications

  • Wide range of detected gases
  • Multi-climate application
  • Expanded temperature range

Reliability and durability

  • 100% of devices tested
  • Long-life sensors
  • Poison resistant sensor
  • Long-term stability

Performance and accuracy

  • Robust protective housing
  • High-speed response
  • Visual and audible alarm

Cost-effective

  • Warranty 1 year
  • Service life 12 years
  • Certified built-in software with protection level “C”

Main technical characteristics

*-available for selected configuration

Modifications
  • DGS ERIS-210-IR (lnfrared sensor)
  • DGS ERIS-210-CAT (Termocatalytic sensor)
  • DGS ERIS-210-EC (Electrochemical sensor)
lndicationStatus LEDs
Interfaces4-20 mA, RS-485 MODBUS RTU, НАRТ 7, LoRaWAN*, E-Wire*, Bluetooth* for settings
Relay outputs
2 alarm, 1 fault. 3 х 2A@220VAC SPDT
lnput voltage range, DC V12 to 36 (nominal 24V)
Temperature range, °С-60 ... +65 (-76°F ... 149°F)
Ex marking1 Ex d [ia Ga] IIC T6 Gb X
Ingress ProtectionIP67
Weight, kg
  • 2.0 (aluminum alloy)
  • 3.9 (S5316 stainless)
Housing
  • painted aluminum
  • stainless steel
Signal Time Т0,9, sec.
  • DGS ERIS-210-IR: 5
  • DGS ERIS-210-CAT: 10
  • DGS ERIS-210-EC: 45
Warm-up time, maximum, minutes
  • DGS ERIS-210-IR: 2
  • DGS ERIS-210-CAT: 10
  • DGS ERIS-210-EC: 10
Rated supply voltage, V
24
The range of input voltage, V
12-32
Power consumption, not exceeding, W
  • DGS ERIS-210-IR: 0,5
  • DGS ERIS-210-CAT: 2
  • DGS ERIS-210-EC: 2
Service life, at least, years
12
Time to failure, h
  • DGS ERIS-210-IR: 70000
  • DGS ERIS-210-CAT: 35000
  • DGS ERIS-210-EC: 35000
The range of ambient temperature and detected gases, °C
  • DGS ERIS-210-IR, CAT, EC:
    from -60 to +65
  • DGS ERIS-210-IR with remote IR sensor:
    from -60 to +90
  • DGS ERIS-210-CAT with remote CAT sensor:
    from -60 to +150

Relative humidity, not exceeding, %

98
Atmospheric pressure range, kPa
from 84 to 106,7
Verification interval, years
  • DGS ERIS-210-IR: 3
  • DGS ERIS-210-CAT: 1
  • DGS ERIS-210-EC: 1
Warranty, years
  • DGS ERIS-210-IR: 3
  • DGS ERIS-210-CAT: 1
  • DGS ERIS-210-EC: 1
Delivery package
  • Gas detector
  • Magnetic key
  • Passport
  • User Manual

Optional equipment (by request)

  • Calibration cap
  • Pipe mounting kit
  • Duct mounting kit
  • Sunshade/deluge protection
  • Cable entry
  • Cable entry cover
Approved measurement accuracy of oil vapors
Yes
List of detected gases

DGS ERIS-210-IR, CAT:

  • Petroleum/oil vapours
  • Methane (CH4)
  • Ethane (C2H6)
  • Propane (C3H8)
  • Butane (C4H10)
  • Isobutane (u-C4H10)
  • Pentane (C5H12)
  • Cyclopentane (C5H10)
  • Hexane (C6H14)
  • Cyclohexane (C6H12)
  • Propene (Propylene) (C3H6)
  • Methanol (CH3OH)
  • Ethanol (C2H5OH)
  • Heptane (C7H16)
  • Ethylene (C2H4)
  • ethylene oxide (C2H4O)
  • Benzene (C6H6)
  • Carbon dioxide (CO2) (IR-210 only)
  • Hydrogen (H2) (TC-210 only)
  • Amyl
  • Acetylene
  • Acetone, dimethyl ketone
  • Acetaldehyde
  • Petrol
  • Gas extraction grade (hexane fraction)
  • Butadiene -1,3
  • Butylenes
  • Butyl alcohol, butanol
  • Water-gas
  • Gas coke ovens
  • Natural gas fuel compressed
  • Gases hydrocarbon liquified
  • Gas kerosene pyrolysis
  • Gas ethane pyrolysis
  • Gas Catalytic Cracking
  • Divinyl
  • Dioxane, dioxane, diethylene
  • Diethyl ether, ethyl ester
  • Dual water gas
  • Isobutyl alcohol, isobutanol
  • Isobutylene
  • Isopropanol isopropanol
  • Isopentane
  • Isoprene
  • Methanol acrylic acid
  • Methyl alcohol, methanol, carbinol, wood alcohol
  • Metiletilkenton, ethyl methyl ketone
  • propylene oxide
  • Carbon monoxide, carbon monoxide
  • Ethylene oxide
  • Propyl alcohol
  • Associated petroleum gas
  • The amount of hydrocarbons
  • Acetic acid
  • Formaldehyde
  • Vapours of oil (a mixture of butane gas and vapor, hexane, methane, pentane, propane, ethane)
  • Ethanol

DGS ERIS-210-EC:

  • Hydrogen sulfide (H2S)
  • Ethylene oxide (C2H4O)
  • Hydrazine (N2H4)
  • Hydrogen chloride (HCL)
  • Hydrogen fluoride (HF)
  • Ozone (O3)
  • Silane (SiH4)
  • Nitric oxide (NO)
  • Nitrogen dioxide (NO2)
  • Ammonia (NH3)
  • Hydrogen cyanide (HCN)
  • Carbon monoxide (CO)
  • Chlorine (Cl2)
  • Sulfur dioxide (SO2)
  • Oxygen (O2)