EKTA

EKTA is an automatic fixed system of continuous action which performs the following functions (depends on the configuration and available optional accessories):
- continuous measurement of the concentration of flammable gases and vapors in processing gas environments;
- continuous measurement of the concentration of hazardous substances and volatile organic compounds (VOCs) in processing gas environments;
- continuous measurement of oxygen concentration, including low concentrations, in processing gas environments;
- warning in case of a threshold value of the concentrations of flammable gases and vapors;
- warning in case of a threshold value of the concentrations of hazardous toxic substances and oxygen;
- operation (on / off) with executive devices and process equipment of the controlled object;
- warning the staff about any emergency situation;
- storing information about the concentration of the measured components, its processing and displaying;
- information transmission to PC and top-level controllers.
The cabinet (rack) allows you to install the following functional blocks (depends on technical specifications):
- Sample transport unit.
Used for transporting samples to the detector (DGS) in a constant quantitative and qualitative state.
- Sample reduction unit.
Used to reduce the sample pressure to the value required for measurement.
- Sample cleaning unit.
Used to clean the sample from the mechanical and aerosol inclusions. In some cases, may be used for absorption filters remove corrosive substances or substances which could compromise the analysis.
- The cooling unit.
Used to cool the hot sample to the temperature required for the measurement and discharge of condensed water.
- Air conditioner (for execution in the closet).
Used for heating or cooling the air inside the cabinet. It maintains the temperature inside the cabinet at +10 ... + 20 ° C (at an ambient temperature of -60 to + 50C).
- The analyzer security module.
Used to prevent sample flow analysis on high-pressurized and / or high temperature.
- Gas detector DGS Eris 200 series.
Used for measuring the concentration of substances in the sample.
- Sample ejection module.
Used for tapping (into the surrounding atmosphere / a candle / refund process) after the sample analysis.
- The sample flow control unit.
Used to prevent incorrect measurements in the absence of sample flow.
- The unit of electrical connections.
Used for the electrical connection equipment.
Field of application (short list):
- Air separation stations. Control of oxygen in inert environments.
- Steaming machines and containers. Control of the oxygen concentration (3-8%) in the vapor medium at the deactivation pyrophoric deposits.
- The suction line of compressors operating under discharge. Control of the oxygen content in the fuel gas in the suction lines; inert gas supply in case of excessing concentrations.
- Transportation and desensitization of solid combustible materials with inert gases. Control of the oxygen content.
- The use of inert gases to displace combustible gases and vapors.
- Oxygen content control in the columns operating under negative pressure, which contain substances that are capable of forming with the oxygen in the air explosive mixtures.
Main characteristics
Maximum pressure of the medium, up to, MPa |
16 |
|||
The gas flow for analysis, not exceeding, dm3/ min |
5 |
|||
Mounting |
Indoors or outdoors (including Ex zones) |
|||
Process connection |
Defined by project |
|||
Power supply, AC, V |
220 |
|||
Power consumption, max, W |
2500 |
|||
Weight, kg |
250 |
|||
Dimensions, max, cm |
2500х1000х800 |
|||
Housing |
|
|||
Operating conditions: |
||||
Ambient temperature, °С |
from -60 to +50 |
|||
Relative humidity, up to, % |
98 (at a temperature of +35 ° C and lower without condensation) |
|||
Average service life, years |
12 |
The list of detected and measured gases, vapors, VOCs |
Flammable gases and vapors:
Toxic gases:
Volatile organic compounds (VOCs):
|